کنترل ماژول برند MSA مدل FM002A Facilities

(MSA Brand Module Model Fm002A Facilities)

MSA Brand Module Model Fm002A Facilities

MSA Brand Module Model Fm002A Facilities

Description

The FM002A is a Facilities Module which provides a range of common facilities for all Zero Two Control Modules housed in the Chassis.

The FM002A is plugged into the last slot on the right hand side of a 4, 8 or 16 Channel Chassis.

Chassis may be daisy-chained whereby one FM002A will serve up to 100 Zero Two Modules of any combination.

Common Alarm Outputs for A1, A2, Fault and UA (Unaccepted alarm)

A Master Reset pushbutton, which resets any latched alarm condition which is no longer valid.

An Accept pushbutton which acknowledges

alarms by de-activating the UA outputs and causing the alarm logic outputs and indicators to revert to a steady ‘ON’.

The FM002A can be supplied with or without alarm relays.

A typical sequence of action would be:

If any Control Module in the Chassis goes into an A1 alarm, then a signal will be bussed to the FM002A,

activating the A1 alarm and UA outputs (open collector and relays).

If the ACCEPT button is pressed, the UA outputs will be de-activated both on the Zero Two Module and the FM002A.

Should the Module go into an A2 Alarm, then a further signal will be sent to the FM002A which will activate the A2 outputs and re-activate the UA.

Pressing the ACCEPT button will again de-activate the UA outputs.

Any subsequent alarms from the Modules will have the same effect in re-activating the pre-accepted UA outputs.

Pressing the MASTER RESET button will de-activate any latched alarms, provided that the gas concentration is lower than the alarm set point,

or in the case of a Fire Signal, if these are no longer activated.

Pressing the MASTER RESET button for a period greater than three seconds will illuminate all displays and LED’s on the Modules in the Chassis.

Features

Master Reset

Alarm Accept

Common Relays for A1, A2, Fault and Unaccepted alarm

Rack LED Test

Serves up to 100 Zero Two Modules in one system

Benefits

No need for external switch

Acknowledges alarm condition in panel without cancelling field alarm

Facilitates flexible system design

Single action test of all LED’s on up to 100 Zero Two Cards

Economy of design

مشخصات فنی

Device Name/ Farsi

کنترل ماژول برند MSA مدل FM002A Facilities

Device Name / English

MSA Brand Module Model Fm002A Facilities

Model / Part Number

Fm002A Facilities

Brand

Origin

Device Type

Control Module

Operating Voltage

Operating Temperature

,

Humidity

Relay outputs

Relays: DPDT, 3 A, 30 VC, 30 V RMS/42.4V Pk resistive max.

Approvals

EMC Compliance

EMC Susceptibility: 10 V/m max

Weight/Dimension

Size: 173x19x251 mm HxWxD | Weight: 8.8 oz (250 grams)