سیستم نمونه گیر گاز برند MSA مدل MultiGard 5000


ویژگی‌های محصول
  • Device Name/ Farsi:  سیستم نمونه گیر گاز برند MSA مدل MultiGard 5000
  • Device Name / English:  MSA Brand Multipoint gas sampling system Model MultiGard 5000
  • Model / Part Number:  MultiGard 5000
  • Brand:  
  • Origin:  
  • Device Type:  Multipoint gas sampling system
+ بیشتر

مقایسه

مشاوره و پشتیبانی به کارشناسان شما

ارائه پیش فاکتور و فاکتور رسمی

امکان مقایسه محصول

ارائه گواهی ضمانت اصل بودن محصولات

پشتیبانی تلفنی قبل و بعد از خرید

توضیحات

سیستم نمونه گیر گاز برند MSA مدل MultiGard 5000

(MSA Brand Multipoint gas sampling system Model MultiGard 5000)

MSA Brand Multipoint gas sampling system Model MultiGard 5000

MSA Brand Multipoint gas sampling system Model MultiGard 5000

Description

MultiGard 5000 Gas Sampling System

Gas samples are drawn from remote locations and delivered to customer-selectable internal analyzers.

Maintenance and calibration are simplified because all maintenance is performed at a single location.

Efficiency

Efficient, cost effective gas detection method.

Gas samples are sequentially delivered to internal analyzers.

Timesharing the analyzers between many monitored locations provides significant cost savings.

This system can include up to four analyzers, reducing floor space, eliminating multiple systems, duplicate tubing, and unnecessary maintenance.

Bypass flow system minimizes sampling cycle time

Reliability

Reliability is enhanced through the use of a single set of analyzers, reducing replacement cost and lowering cost of ownership

Maintenance and calibration are simplified because all maintenance is performed at a single location.

All calibrations are completed at the MultiGard 5000 System analyzer(s), with no need to enter the monitored area.

Manual or auto-standardization of sensors or analyzers when desired

Control

To alert personnel, four common relays are provided.

Additional user-configurable relays are available for discrete alarms.

Gas concentrations and alarm settings can be exported to a flash drive in .

CSV format.

Flexibility

MultiGard 5000 System adapts to provide optimum time for a given analyzer.

Each location can have a different sample transport time (based on line length).

Critical sampling points can be sampled more frequently.

An optional dual- sequencer system can be used, in which up to two analyzers are dedicated to each half of the sampling points

Data stored on SD card for easy transfer.

Connectivity

The MultiGard 5000 System directly connects to Modbus TCP or BACnet IP networks, industry-standards which permit communication to other equipment or controllers.

Via these protocols, the MultiGard 5000 Gas Sampling System links to most distributed communication system networks.

Remote option allows viewing of current readings and controlling of the system settings from any location.

Typical Applications

Parking garage ventilation systems

Curing or finishing processes

Process control

LNG or CNG transport ships

Perimeter monitoring

Ambient or IAQ (indoor air quality) monitoring

Solid foam production

Hydrogen furnaces

Semiconductor manufacturing

Aerosol packaging

Food & beverage

Bus, vehicle facilities, and tunnels

Security

A password is needed to change any system parameter.

Internal battery will keep all data intact for up to two years.

Overview screen provides quick visual

indication of MultiGard 5000 System status

Ordering Information

MultiGard 5000 Gas Sampling System ATO order form is available upon request.

مشخصات فنی

Device Name/ Farsi

سیستم نمونه گیر گاز برند MSA مدل MultiGard 5000

Device Name / English

MSA Brand Multipoint gas sampling system Model MultiGard 5000

Model / Part Number

MultiGard 5000

Brand

Origin

Device Type

Multipoint gas sampling system

Operating Temperature

Humidity

Output voltage

COMMON RELAYS: Form C contacts (SPDT), 8 amp, 250 VAC optional user-configurable |, DISCRETE RELAYS: Form C contacts (SPDT), 10 amp, 250 VAC optional user-configurable |, SOLID STATE OUTPUTS: 100 mA @ 24 VDC, sinking

Weight/Dimension

8/16/DUAL 8: Size: (609.6 x 762 x 304.8 mm) W x H x D WEIGHT: 56.7 kg | 24/32/DUAL 16: DIMENSIONS: (762 x 762 x 304.8 mm) W x H x D WEIGHT: 68 kg

ENCLOSURE

ENCLOSURE: NEMA, General purpose for non-hazardous areas enclosure rating

OPERATOR INTERFACE

OPERATOR INTERFACE: TYPE: Integrated color TFT touch-screen display, SIZE: 10.5 “ (267 mm) diagonal

POWER REQUIREMENTS

POWER REQUIREMENTS: 5 amp @ 115 VAC, 60 Hz, single sequencer systems, 10 amp @ 115 VAC, 60 Hz, dual sequencer systems, Electrical entry through gasketed gland plate

FLOW SYSTEM

FLOW SYSTEM: LOOK AHEAD BYPASS
CONNECTIONS: 1/8 NPT, SAMPLE LINE TUBING: 500 ft. (152 m) max. w/0.250” (6.35 mm) OD, 0.175” (4.4 mm) ID tubing
(Longer line lengths possible with custom pumps. Consult factory), SAMPLE LINE FLOW RATE: 0.175” (4.4 mm) ID tubing; 20 SCFH (10 lpm) typical,
no-load 10 SCFH (5 lpm) typical, full load.

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “سیستم نمونه گیر گاز برند MSA مدل MultiGard 5000”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *