دتکتور شعله ضد انفجار برند Honeywell مدل Fire Sentry SS2


ویژگی‌های محصول
  • Device Name/ Farsi:  دتکتور شعله ضد انفجار برند Honeywell مدل Fire Sentry SS2
  • Device Name / English:  Honeywell Brand flame detector Model Fire sentry SS2
  • Model / Part Number:  SS2-A | SS2-AN Multi-Spectrum
  • Brand:  
  • Origin:  
  • Type of Sensor:  
+ بیشتر

مقایسه

مشاوره و پشتیبانی به کارشناسان شما

ارائه پیش فاکتور و فاکتور رسمی

امکان مقایسه محصول

ارائه گواهی ضمانت اصل بودن محصولات

پشتیبانی تلفنی قبل و بعد از خرید

توضیحات

دتکتور شعله ضد انفجار برند Honeywell مدل Fire Sentry SS2

(Honeywell Brand flame detector Model Fire sentry SS2)

Honeywell Brand flame detector Model Fire sentry SS2

Honeywell Brand flame detector Model Fire sentry SS2

 

SS2-A & SS2-AN Multi-Spectrum

Digital Electro-Optical Fire Detector

Description

Fire Sentry SS2-A and Fire Sentry SS2-AN

The Fire Sentry SS2-A, (latching Fire Alarm relay), and Fire Sentry SS2-AN (nonlatching

Fire Alarm relay), represent the world´s pre-eminent UV/IR technology

for Electro-Optical fire and flame detectors, with thousands successfully

operating in a multitude of installations worldwide. This detector senses radiant

energy in the Ultraviolet (UV), Visible and Wide Band IR™ spectrum. The radiant

energy from all types of flaming fires will alert the detector to their presence.

The field-of-view is the widest in the industry with a 120° cone of vision. This

means each detector can cover more hazard area. Greater sensitivity also

increases the volume of coverage by the detector, up to four times more than

some other detectors.

Fire Sentry SS2-AM and Fire Sentry SS2-AML

The Fire Sentry SS2-AM, (latching Fire Alarm relay), and Fire Sentry SS2

AML (non-latching Fire Alarm relay), represent the world´s pre-eminent Ultra-

High Speed UV/IR technology for Electro-Optical fire and flame detectors,

successfully operating in a multitude of installations worldwide. This detector

senses radiant energy in the Ultraviolet (UV), Visible and Wide Band IR™

spectrum. The radiant energy from all types of flaming fires will alert the detector

to their presence.

The field-of-view is the widest in the industry with a 120° cone of vision. This

means each detector can cover more hazardous area.

Features

Multi-Spectrum senses energy in the UV, Vis and WideBand IR™

False alarm immunity

Detects hydrocarbon and non-hydrocarbon fires

Microprocessor based algorithms: FirePic™ and Tri-Mode Plot™

Wide field of view and solar blind

Wide temperature range of operation

Explosion-proof housing

FS2000™ System compatible or standalone operation

Compatible with approved fire alarm panels

SS2-A & SS2-AN UV/IR Digital Fire and Flame Detector

Oil, Gas & Petrochemical Facilities

Gas Turbines

Compressor Stations

Power Plants

Silane & Hydrogen Gas Storage

Aircraft Hangers

Warehouses

SS2-AM & SS2-AML UV/IR Ultra-High Speed Digital Fire and Flame Detector

Munitions production

Explosives production

Manufacture of other explosive material

Silane & Hydrogen gas storage

SS2-AH & SS2-AHD UV/IR Ultra-High Speed Digital Fire and Flame Detector

Sodium Azide propellant manufacture

Automotive Air Bag manufacture

Operation

The SS2 operates from standard 24 Volt DC power and interfaces to approved fire alarm panels or standard PLC’s.

When power is applied, an internal self test is performed and the fault relay resets to show no faults.

The detector is then in normal operation.

The front LEDs flash every ten seconds to indicate power is on.

The continuous spectral data stream of information from the sensor array is analyzed by the microprocessor.

On Alarm, the detector activates the alarm relay and stores all of the pre-fire spectral data from the sensor array in nonvolatile memory for retrieval and evaluation.

This Fire Pic™ data can be used to postulate the cause of the fire.

As part of the FS2000™ System, the the lens and complete optical path can be checked using COP-i™ Test Sources in the system.

Connection into the FS2000™ System is by the four wire RS-485 FireBus™.

The field of view for the Fire Sentry SS4 detectors is the widest in the industry with a 120° cone of vision.

This means more hazard area can be covered by each detector.

Greater sensitivity also increases the volume covered by each detector, up to four times more than some other detectors.

Using sophisticated microprocessor signal processing algorithms, false alarm rejection is maximized – with virtual immunity to false alarms from arc welding, corona discharge and other common non-fire sources.

مشخصات فنی

Device Name/ Farsi

دتکتور شعله ضد انفجار برند Honeywell مدل Fire Sentry SS2

Device Name / English

Honeywell Brand flame detector Model Fire sentry SS2

Model / Part Number

SS2-A | SS2-AN Multi-Spectrum

Brand

Origin

Type of Sensor

Operating Voltage

(Power Consumption(Standby

(Power Consumption(Alarm

Response Time

Adjustable Time Delay

Sensitivity Ranges

Spectral Response

Field Of View

(Built-In-Test (BIT

Operating Temperature

Humidity

Ingress Protection

IP66

Area-Classification

Approvals

Case Material